Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 189
Filter
1.
Article in English | LILACS-Express | LILACS | ID: biblio-1528851

ABSTRACT

The present study analyzed the microhardness and degree of conversion of three Bulk Fill resins (M1 - Filtek Bulk Fill; M2 - Tetric N-Ceram Bulk Fill and M3 - Opus Bulk Fill) polymerized by single peak and polywave Light-emitting Diode Curing Lights. A total 90 test specimens (n=10) were obtained using a Teflon matrix for the purpose of testing microhardness; and for degree of conversion: 135 specimens (n=5) by using a 2 x 6 cm matrix. The specimens were light polymerized using 3 light sources (L1 - Optilight Max, L2 - Bluephase, L3 - VALO). They were kept in artificial saliva om an oven at 37±1°C during the experiment. The degree of conversion was measured by FTIR 24 h after obtaining each test specimen. The microhardness readouts were performed with a microdurometer at the time intervals of 48 hours (T0), 7 days (T1), 14 days (T2) and 21 days (T3). M1L3 was found to show the highest microhardness values in T2, and M1 showed the lowest degree of conversion in the deep third with L1. It was concluded that Filtek Bulk Fill resin showed the best results in comparison with the other resins.


El presente estudio analizó la microdureza y el grado de conversión de tres resinas Bulk Fill (M1 - Filtek Bulk Fill; M2 - Tetric N-Ceram Bulk Fill y M3 - Opus Bulk Fill) polimerizadas por lámparas de curado de diodo emisor de luz de pico único y polionda. Se obtuvieron un total de 90 especímenes de prueba (n=10) utilizando una matriz de teflón con el propósito de probar la microdureza; y para grado de conversión: 135 especímenes (n=5) utilizando una matriz de 2 x 6 cm. Las muestras se fotopolimerizaron utilizando 3 fuen- tes de luz (L1 - Optilight Max, L2 - Bluephase, L3 - VALO). Se mantuvieron en saliva artificial en estufa a 37 ±1°C durante el experimento. El grado de conversión se midió por FTIR 24 h después de obtener cada muestra de prueba. Las lecturas de microdureza se realizaron con un microdurómetro en los intervalos de tiempo de 48 horas (T0), 7 días (T1), 14 días (T2) y 21 días (T3). Se encontró que M1L3 mostraba los valores más altos de microdureza en T2, y M1 mostraba el grado más bajo de conversión en el tercio profundo con L1. Se concluyó que la resina Filtek Bulk Fill mostró los mejores resultados en comparación con las demás resinas.

2.
Rev. cuba. estomatol ; 60(4)dic. 2023.
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1550856

ABSTRACT

Objetivo: Comparar el efecto de antibióticos pediátricos sobre la microdureza superficial del esmalte dental en dientes bovinos. Métodos: Se realizó un estudio in vitro en 60 dientes bovinos no cariados. Se sumergieron 15 dientes en cada grupo de cuatro soluciones (amoxicilina, amoxicilina + ácido clavulánico, eritromicina y saliva artificial) durante 1 minuto tres veces al día durante 7 y 14 días. Se midió la microdureza de la superficie del esmalte al inicio, a los7 y 14 días de exposición a los antibióticos. Resultados: La microdureza superficial del esmalte de los dientes de los grupos de antibióticos pediátricos se redujo después de 7 y 14 días de exposición con diferencia significativa (p < 0,001), respecto a la microdureza inicial. Además, en el grupo expuesto a saliva artificial no hubo diferencia significativa (p = 0,097) en los diferentes tiempos de evaluación. Conclusiones: Se concluye que los antibióticos pediátricos afectan la microdureza del esmalte, siendo la eritromicina la que mayor disminución generó a los 14 días de exposición.


Objective: To compare the effect of pediatric antibiotics on the superficial microhardness of dental enamel in bovine teeth. Methods: An in vitro study was carried out on 60 non carious bovine teeth. Fifteen teeth were immersed in each group of four solutions (amoxicillin, amoxicillin + clavulanic acid, erythromycin and artificial saliva) for 1 minute three times a day for 7 and 14 days. Enamel surface microhardness was measured at baseline, 7 and 14 days of antibiotic exposure. Results: The enamel surface microhardness of the teeth of the pediatric antibiotic groups was reduced after seven and 14 days of exposure with significant difference (p < 0.001), with respect to the initial microhardness. In addition, in the group exposed to artificial saliva there was no significant difference (p = 0.097) at the different evaluation times. Conclusions: It is concluded that pediatric antibiotics affect enamel microhardness and erythromycin generated the greatest decrease at 14 days of exposure.

3.
Odontol.sanmarquina (Impr.) ; 26(3): e24730, jul.-set.2023.
Article in English | LILACS-Express | LILACS | ID: biblio-1538051

ABSTRACT

Objetive. Human teeth have been commonly used for in vitro and in situ studies. Cu­rrently, other animals' teeth have been purposed for dental research to overcome human teeth' problematic availability. This study aimed to investigate the enamel and dentin from human, bovine, and ovine teeth concerning the microhardness, organic, and in­ organic contents via micro­Raman spectroscopy. Methods. Human, bovine, and ovine teeth were divided according to their type and age into seven groups: Ovine; Bovine­12 months; Bovine­24 months; Bovine­36 months; Bovine­48 months; Bovine­+60 months; Human (control). The enamel's microhardness (superficial and deep) and den­tin (superficial, middle, and deep) were analyzed. The calcium/phosphate ratio and am­ide contents were determined by micro­Raman spectroscopy. Results. Overall, the mi­crohardness of human enamel was superior to the other species. Dentin's microhardness was similar among groups. Ovine group showed lower values of calcium/phosphate ratio than human. Amide content was similar between bovine and human. The microhardness and calcium/phosphate ratio of enamel and dentin, respectively, decreased as the age of bovine teeth increased. Conclusions. Researchers must be aware and take into consider­ation the differences of ovine and bovine enamel compared to human enamel. Other al­ternatives that are more similar to the microhardness of human enamel should be sought. Bovine teeth of 12 and 24 months are suitable substitutes for dentin of human teeth. Researchers must also be aware of the age of the animals and specify it in the studies.


Objetivo. Los dientes humanos se han utilizado comúnmente para estudios in vitro e in situ. Actualmente, los dientes de otros animales se han destinado a la investiga­ción dental para superar la disponibilidad problemática de los dientes humanos. Este estudio tuvo como objetivo investigar el esmalte y la dentina de los dientes humanos, bovinos y ovinos en relación con la microdureza y los contenidos orgánicos e inor­gánicos a través de la espectroscopia micro­Raman. Métodos. Los dientes humanos, bovinos y ovinos se dividieron según su tipo y edad en siete grupos: Ovinos; Bovino­12 meses; Bovino­24 meses; Bovino­36 meses; Bovino­48 meses; Bovino­+60 meses; Hu­mano (control). Se analizó la microdureza del esmalte (superficial y profunda) y de la dentina (superficial, media y profunda). La relación calcio/fosfato y los contenidos de amida se determinaron mediante espectroscopía micro­Raman. Resultados. En general, la microdureza del esmalte humano fue superior a la de otras especies. La microdureza de la dentina fue similar entre los grupos. El grupo ovino mostró valores más bajos de la relación calcio/fosfato que el humano. El contenido de amida fue similar entre bovinos y humanos. La microdureza y la relación calcio/fosfato del esmalte y la dentina, respectiva­mente, disminuyeron a medida que aumentaba la edad de los dientes bovinos. Conclusiones. El esmalte de los dientes ovinos y bovinos no es un sustituto adecuado del de los dientes humanos. Se deben buscar otras alternativas que sean similares a la microdureza del esmalte humano. Sin embargo, los dientes bovinos de 12 y 24 meses son sustitutos adecuados de la dentina de los dientes humanos. Los investigadores deben conocer la edad de los animales y especificarla en los estudios.

4.
Odontol.sanmarquina (Impr.) ; 26(3): e25460, jul.-set.2023.
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1538052

ABSTRACT

Objetivo. Comparar la dureza, estabilidad dimensional y resistencia a la compresión de los yesos dentales de alta resistencia y baja expansión disponibles en el Perú. Métodos. Se realizó un estudio descriptivo, observacional y transversal. Se confeccionaron muestras de forma cilíndrica (8) y rectangular (8), de siete yesos dentales de alta resistencia y baja expansión. Se evaluó la dureza utilizando el Durómetro Universal Identec, la estabilidad dimensional con un calibrador digital y la resistencia a compresión con la Máquina de Ensayo Universal. Para determinar si hay diferencia en cada una de estas propiedades se empleó el análisis de varianza, la prueba F y la prueba de Duncan. Además, se empleó la prueba de comparación de medias, t de Student, para evaluar si difieren con los valores de la ADA (Asociación Dental Americana). Resultados. La dureza, estabilidad dimen-sional y resistencia a la compresión promedio de los yesos dentales presentó diferencias significativas (p<0.05) entre cada uno con los promedios estándares establecidos por la ADA. Conclusiones. En relación resistencia a la compresión el 100% de los yesos analizados cumplen con los parámetros establecidos por la ADA, en relación estabilidad dimensional solo el 28.6% y el 100% no alcanzan los estándares de dureza promedio establecidos por la ADA.


Objective. To compare the hardness, dimensional stability, and compressive strength of high-strength, low-expansion dental plasters available in Peru, according to ADA criteria. Methods. A descriptive, observational and cross-sectional study was developed. A selection of 8 cylindrical-shaped samples and 8 rectangular- shaped ones, from seven high-resistance, low-expansion dental plasters were fabricated. The hardness was evaluated using the Identec Universal Durometer. Dimensional stability was evaluated with a digital caliper and compressive strength was evaluated with the Instron Universal Testing Machine. To determine if there is a difference in each of these properties, the analysis of variance, F test, and the Duncan's test were used. In addition, to assess whether these values differ from those of the ADA, the mean comparison test, student's t table, were used. Results. The hardness, dimensional stability and average compressive strength of the high-strength, low-expansion dental plasters showed that there are significant di-fferences (p<0.05) between each of the dental plasters and with the standard averages established by the American Dental Association. (ADA). Conclusions. 100% of the high-strength, low-expansion dental casts meet the parameters established by the ADA in terms of their compressive strength, only 28.6% of these comply with the ADA in terms of dimensional stability and that 100% of these do not meet the average hardness standards established by the ADA.

5.
Acta odontol. latinoam ; 36(1): 15-23, Apr. 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1447071

ABSTRACT

ABSTRACT After ozone therapy for bleaching, it is important to evalúate enamel surface properties, to ensure that bleaching provides adequate conditions for sound dental substrate. Aim: The aim of this in vitro study was to evaluate the effects of a bleaching treatment with 10% carbamide peroxide (CP), with or without ozone (O), on the microhardness, roughness and micromorphology of the enamel surface. Materials and Method: Bovine enamel blocks were planed and distributed among the following three bleaching treatment groups (n=10): CP - 1 hour per day/14 days (Opalescence PF 10%/ Ultradent); O - 1 hour per day every 3 days/3 sessions (Medplus VPhilozon, 60 mcg/mL and oxygen flow rate of 1 L/min); and OCP - CP with O, 1 hour per day every 3 days/3 sessions. Enamel surface microhardness (Knoop), roughness (Ra), and micromorphology by scanning electron microscopy (5,000x magnificaron) were determined before and after the treatments. Results: ANOVA and Tukey-Kramer's test showed that enamel microhardness remained unchanged by treatment with O and OCP (p=0.0087), but decreased by treatment with CP. Treatment with O promoted higher enamel microhardness than the other groups (p=0.0169). Generalized linear mixed models for repeated measures over time indicated treatment with CP increased enamel roughness more than OCP or O (p=0.0003). CP produced slight irregularities in enamel micromorphology after the whitening treatment. O, with or without CP, maintained the mechanical and physical properties of microhardness and enamel surface micromorphology, and either maintained or reduced surface roughness, compared to the conventional tray-delivered CP bleaching treatment. Conclusions: Treatment with 10% carbamide peroxide in trays promoted greater changes in enamel surface properties than treatments with ozone and with 10% ozonized carbamide peroxide in the office.


RESUMO É importante avaliar as propriedades da superficie do esmalte após a aplicagao da ozonioterapia para clareamento, para garantir que o efeito clareadorproporcione condigoes adequadaspara um substrato dentário higido. Objetivo: O objetivo deste estudo in vitro foi avaliar os efeitos de um tratamento clareador com peróxido de carbamida (PC) a 10%, associado ou nao ao ozonio (O), na microdureza, rugosidade e micromorfologia da superficie do esmalte. Materials e Método: Blocos de esmalte bovino foram aplainados e distribuidos entre tres grupos de tratamento clareador (n=10): PC - 1 hora por dia/14 dias (Opalescence PF 10%/ Ultradent); O - 1 hora por dia a cada 3 dias/3 sessoes (Medplus VPhilozon, 60 mcg/mL e fluxo de oxigenio de 1 L/min); e PCO - CP com O, 1 hora por dia a cada 3 dias/3 sessoes. A microdureza (Knoop), a rugosidade (Ra) e a micromorfologia da superficie do esmalte avaliada por microscopia eletronica de varredura (aumento de 5.000x) foram analisadas antes e após os tratamentos. Resultados: ANOVA e teste de Tukey-Kramer mostraram que O e PCO mantiveram os valores de microdureza do esmalte ao final do tratamento (p=0,0087), enquanto PC promoveu diminuigao da microdureza. O promoveu maiores valores de microdureza do esmalte do que os outros grupos ao final do tratamento (p=0,0169). Modelos lineares generalizados mistos para medidas repetidas no tempo indicaram um aumento na rugosidade da superficie para PC, levando a maior rugosidade do esmalte ao final do tratamento, em comparagao com PCO ou O (p=0,0003). PC apresentou pequenas irregularidades na micromorfologia do esmalte após o tratamento clareador. O, com ou sem PC, manteve as propriedades mecánicas e fisicas de microdureza e micromorfologia da superficie do esmalte, e manteve ou reduziu a rugosidade da superficie, em comparagao com o tratamento clareador a base de PC aplicado em moldeira convencional. Conclusoes: O tratamento com peróxido de carbamida a 10% para uso em moldeiras promoveu maiores alteragoes nas propriedades de superficie do esmalte do que aquelas observadas nos tratamentos com ozonio e com peróxido de carbamida ozonizado a 10% para uso em consultório.

6.
Acta odontol. latinoam ; 36(1): 40-46, Apr. 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1447074

ABSTRACT

ABSTRACT During ceramic veneer luting, resin cement polymerization is performed with interposition of the dental ceramic. Aim: To evaluate how and how much the photoactivation time affects the Vickers hardness of resin-based cements with interposed ceramic. Materials and Method: A total 24 specimens H mm in diameter and 1 mm thick were made from Paracore White Coltene (PC), Densell Resin Duo Cement (DC), 3MRelyX Veneer (RX) and Coltene Fill Up! (FU), interposing VitablockMarkII (Vita Zahnfabrik) feldspathic ceramic 0.6 mm thick during photoactivation. The materials were polymerized using 100% and 25% of the times indicated by the manufacturers with a Coltolux LED ((Coltene) light with intensity 1200 mW/cm2. Each polymerization time group consisted of three specimens of each material, which were stored dry in darkness at 37 °C for 7 days. Three Vickers microhardness measurements were made on the top and bottom surfaces of each specimen using a Vickers Future Tech FM300 microhardness tester (300 g, 5 s). The values were averaged, and the bottom/top ratios calculated. Results were analyzed by ANOVA. (p<0.05) complemented with multiple comparisons using Tukey's test (p<0.05). Results: Different photoactivation times were found to have a significant effect on hardness values of the cements evaluated, with significant differences between some of the cements. No statistically significant difference was found for the effect of photoactivation time on bottom/top microhardness ratio in those materials. Conclusions: Under the experimental conditions employed, it can be concluded that photopolymerization for shorter times and the interposition of restorative material significantly affectpolymerization quality as evaluated by microhardness, but the bottom/top ratio was unaffected by differences in polymerization time.


RESUMEN Durante la fijación de una carilla cerámica, la polimerización del cemento a base de resinas se realiza con la interposición de la cerámica dental. Objetivo: evaluar en qué forma y magnitud afecta el tiempo de fotoactivación en la dureza Vickers de los cementos a base de resinas con la cerámica interpuesta. Materiales y Método: se confeccionaron 24 probetas de 11 mm de diámetro y 1 mm de espesor con: Paracore White Coltene (PC), Resin Duo Cement de Densell (DC), RelyX Veneer de 3M (RX) y Fill Up! De Coltene (FU) interponiendo 0,6 mm de espesor de cerámica feldespática Vitablock Mark II (Vita Zahnfabrik) durante la fotoactivación. Se polimerizó utilizando el 100% y el 25% del tiempo indicado por el fabricante con lámpara Coltolux LED ((Coltene) con 1200 mW/cm2 de intensidad. Cada grupo quedó conformado con tres probetas de cada material que se almacenaron a oscuras y en seco a 37 °C durante 7 días. Se registraron tres mediciones de microdureza Vickers de las superficies top y bottom de cada probeta con un microdurómetro Vickers Future Tech FM300 (300 g, 5 s) y se calculó su promedio, así como la relación entre los valores registrados en cada una de sus caras. Los resultados fueron analizados por medio de la prueba de ANOVA. (p<0.05). complementada con comparaciones múltiples por medio de la prueba de Tukey (p<0.05). Resultados: se encontró un efecto significativo de la modificación del tiempo de fotoactivación en los valores de dureza de los cementos evaluados con diferencias significativas entre algunos de ellos. Simultáneamente no se encontró significación estadística en el efecto de ese factor sobre la relación microdureza bottom/top registrada en esos materiales. Conclusiones: en las condiciones experimentales empleadas puede concluirse que la fotopolimerización en menor tiempo e interposición de material restaurador afecta significativamente la calidad de polimerización evaluada mediante los valores de microdureza, pero la proporción bottom/ top no fue afectada en la variación en el tiempo de polimerización.

7.
Acta odontol. latinoam ; 36(1): 58-65, Apr. 2023. tab
Article in English | LILACS-Express | LILACS | ID: biblio-1447077

ABSTRACT

ABSTRACT Color stability is among the most frequent causes of restoration failures, and influences surface properties. Aim: The aim of this study was to investigate the influence of pigment solutions on low-shrinkage and conventional composites regarding changes in the physical properties of composite surfaces. Materials and Method: Specimens of four composites (Filtek Z350 XT, Point 4, N'Durance and Venus Diamond) were randomly distributed into three groups to be submitted to each of three pigment solutions (red wine, tomato sauce and coffee) in fifteen-minute daily cycles, for twenty-eight days. There were 12 groups altogether (n = 10). Color, surface roughness and hardness tests were performed. Statistical analysis includedAnalysis of variance (ANOVA) and Tukey's significance test (a = 0.05). Results: Color changes caused by the solutions did not differ significantly among Filtek Z350 XT, Venus Diamond and N'Durance. Hardness decreased significantly in Filtek Z350 XT and Venus Diamond after chemical challenge with each solution. For the composite independent factor, roughness was highest in Venus Diamond, followed by Filtek Z350 XT, Point 4 and N'Durance. Conclusions: Treatment with different pigment solutions (red wine, tomato sauce or coffee) increased stainability and decreased hardness of both low-shrinkage and conventional composites, while roughness was unaffected.


RESUMO A estabilidade de cor está entre as causas mais frequentes de falhas de restauragoes, que também influenciam suas propriedades superficiais. Objetivo: O objetivo do presente estudo foi investigar a influencia de solugoes de pigmentos em compósitos convencionais e de baixa retragao, bem como alteragoes naspropriedades físicas da superficie dos compósitos. Materiais eMétodo: Amostras de cada compósito (Filtek Z350XT, Point 4, N'Durance e Venus Diamond) foram distribuidas aleatoriamente em grupos submetidos a cada solugao pigmentante (vinho tinto, molho de tomate e café) em ciclos diários de quinze minutos, durante vinte e oito dias. Assim, totalizando 12 grupos (n = 10). Foram realizados testes de cor, rugosidade superficial e dureza. A Análise Estatistica foi realizada usando Análise de variáncia (ANOVA) e o teste de significáncia de Tukey (a = 0.05). Resultados: As alteragoes de cor desencadeadas pelas solugoes investigadas nao mostraram diferenga estatisticamente significativa entre os compósitos Filtek Z350 XT, Venus Diamond e N'Durance. Os valores de dureza registrados para Filtek Z350XT e Venus Diamond diminuiram significativamente após o desafio químico com cada uma das solugoes pigmentantes. Para o fator independente compósito, Venus Diamond registrou a maior rugosidade; foi seguido por Filtek Z350XT, Point 4 e N'Durance. Conclusoes: Os tratamentos das amostras com diferentes solugoes pigmentantes (vinho tinto, molho de tomate e café) aumentaram a manchabilidade dos compósitos convencionais e de baixa retragao e diminuiram sua dureza, embora nao tenham afetado a rugosidade dos compósitos.

8.
RGO (Porto Alegre) ; 71: e20230057, 2023. tab
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1521435

ABSTRACT

ABSTRACT Objective: To evaluate the effect of thermocycling on the Knoop internal microhardness of high- and low viscosity bulk fill resins applied in Class I cavities. Methods: Thirty third molars with Class I cavity preparations were randomly divided into 3 groups according to the restorative system: nanoparticulated composite resin (Filtek™ Z350 XT 3M ESPE) (oblique increments of 2mm); low viscosity bulk fill resin (Filtek™ Bulk fill Flow, 3M ESPE) (3mm increments covered with a 1-mm layer of nanoparticulated resin); high viscosity bulk fill resin (Filtek™ Bulk fill, 3M ESPE) (single 4-mm increment). After 24h, half of samples was submitted to thermocycling (1,000 cycles). All samples (n=5) were sectioned in half to measure the internal microhardness at bottom and top of restoration. Results: Analysis of variance indicated that, for nanoparticulated composite resin, without thermocycling, the microhardness at the top was statistically lower than at the bottom. After thermocycling, there was no difference in microhardness between the top and the bottom. For low viscosity bulk fill resin, without thermocycling, there was no significant difference in microhardness means between the top and the bottom. After thermocycling, significantly higher microhardness was found at the top than at the bottom (p <0.05). For high viscosity bulk fill resin there was no significant difference between the microhardness values at the top and bottom, regardless of thermocycling (p> 0.05). In all composite resins, an increase in microhardness was observed after thermocycling (p <0.05). Conclusion: Thermocycling increased the internal microhardness of resin restorations, and, for the low viscosity bulk fill resin, the microhardness at the top was higher than at the bottom after thermocycling.


RESUMO Objetivo: Avaliar o efeito da termociclagem na microdureza Knoop interna de resinas bulk fill de alta e baixa viscosidade aplicadas em cavidades classe I. Métodos: Trinta terceiros molares com cavidades Classe I foram divididos aleatoriamente em três grupos de acordo com o sistema restaurador: Resina composta nanoparticulada (Filtek™ Z350 XT 3M ESPE) (incrementos oblíquos de 2mm); resina bulk fill de baixa viscosidade (Filtek™ Bulk fill Flow, 3M ESPE) (incremento de 3mm mais 1mm de resina nanoparticulada); resina bulk fill de alta viscosidade (Filtek ™ Bulk fill, 3M ESPE) (único incremento de 4mm). Após 24h, metade das amostras foi submetida a termociclagem (1.000 ciclos). Todas as amostras (n=5) foram seccionadas ao meio para mensuração da microdureza interna na base e topo da restauração. Resultados: Análise de variância indicou que, para a resina composta nanoparticulada e antes da termociclagem, a microdureza no topo foi estatisticamente inferior do que na base (p<0,05). Após a termociclagem, não houve diferença entre topo e base. Já para a resina bulk fill de baixa viscosidade, antes da termociclagem, não se constatou diferença significativa nos valores de microdureza entre topo e base. Após termociclagem, valores significativamente mais elevados de microdureza foram encontrados no topo do que na base (p<0,05). Para resina bulk fill de alta viscosidade, não houve diferença significativa na microdureza entre topo e base, realizando-se ou não termociclagem (p>0,05). Em todas as resinas compostas foi verificado aumento de microdureza após termociclagem (p<0,05). Conclusão: A termociclagem aumentou a microdureza para todas as resinas compostas, sendo que para a resina bulk fill de baixa viscosidade a microdureza no topo foi maior do que na base após termociclagem.

9.
Rev. Fac. Odontol. Porto Alegre (Online) ; 63(2): 12-23, jul.-dec. 2022.
Article in English | LILACS-Express | LILACS | ID: biblio-1525488

ABSTRACT

Aim: Stevia rebaudiana Bertoni (Stevia) is a natural non--caloric sweetener that can modify the cariogenicity of biofilms. This study aimed to evaluate the effect of Ste-via infusion in microbial and biochemical composition of biofilms formed in the presence of sucrose and on enamel demineralization. Materials and Methods: In a cross-over design, eleven volunteers wore an intraoral palatal appliance containing 4 slabs of bovine enamel during 3 phases of 7 days each. Sucrose solution (20%) was dripped onto slabs 8 times/day and 0.9% sodium chloride (NaCl), 0.12% chlorhexidine (CHX), or 5% infusion of Stevia were dripped 2x/day. Biofilm formed on the slabs was collected and analyzed for counts of microorganisms (total bacteria, Lactobacilli, Candida spp., and Streptococcus mutans) biochemical composition in terms of soluble and insoluble extracellular polysaccharides and qualitative assessment by scanning electron microscopy. The per-centage of surface hardness loss (%SHL) was determined on enamel slabs taken baseline and post-biofilm Knoop surface hardness values. Results: The % SHL in the CHX treatment was statistically lower in comparison to NaCl (p < 0.05). No differences were found between Stevia and CHX and between Stevia and NaCl. No other difference was found among the experimental groups with respect to the other outcomes. Discussion: Under high carioge-nic conditions resembling frequent exposure to sucrose and absence of mechanical disruption, use of Stevia can neither modify the counts of cariogenic microorganisms nor the concentration of extracellular polysaccharides on in situ formed biofilms. This may have occurred due to the exposure of the biofilm to high sucrose concentration for all treatments and the condi-tion of the microorganism growth in situ, which may hinder the diffusion of substances through the thick biofilm. Conclusion: Biofilm exposed to a high cariogenic challenge and without mechanical disruption is not affected by an infusion of Stevia rebaudiana Bertoni.


Objetivo: A Stevia rebaudiana Bertoni (Stevia) é um adoçante natural não calórico que pode modificar a cariogenicidade de biofilmes. Este estudo teve como objetivo avaliar o efeito da infusão de Stevia na composição microbiana e bioquímica de biofilmes formados na presença de sacarose e na desmineralização do esmalte. Materiais e métodos: Em um desenho cruzado, onze voluntários usaram um aparelho intraoral palatino contendo 4 pla-cas de esmalte bovino durante 3 fases de 7 dias cada. A solução de sacarose (20%) foi gotejada em placas 8 vezes/dia e cloreto de sódio a 0,9% (NaCl), clorexidina a 0,12% (CHX) ou infusão a 5% de Stevia foram gotejados 2x/dia. O biofilme formado nas placas foi coletado e analisado para contagem da composição bioquímica de microrganismos (bactérias totais, Lactobacilos, Candida spp. e Streptococcus mutans) em termos de polissaca-rídeos extracelulares solúveis e insolúveis e avaliação qualitativa por microscopia eletrônica de varredura. A porcentagem de perda de dureza superficial (%SHL) nos blocos de esmalte foi determinada com base nos valores de dureza superficial Knoop tomadas no início e pós-biofilme. Resultados: O % SHL no tratamento CHX foi estatisticamente menor em comparação ao NaCl (p < 0,05). Não foram encontradas diferenças entre Stevia e CHX e entre Stevia e NaCl. Nenhuma outra diferença foi encontrada entre os grupos experimentais em re-lação aos outros resultados. Discussão: Sob condições cariogênicas elevadas que se assemelham a exposição frequente à sacarose e ausência de disrupção mecânica, o uso de Stevia não pode modificar as contagens de microrganismos cariogênicos nem a concentração de polissacarídeos extracelulares em biofilmes formados in situ. Isso pode ter ocorrido devido à exposição do biofilme à alta concentração de sacarose para todos os tratamentos e à condição de crescimento do microrganismo in situ, o que pode dificultar a difusão de substâncias através do biofilme espesso. Conclusão: O biofilme exposto a um alto desafio cariogênico e sem disruptucao mecânica não é afetado por uma infusão de Stevia rebaudiana Bertoni.

10.
Natal; s.n; 14 nov. 2022. 53 p. tab, ilus, graf.
Thesis in Portuguese | LILACS, BBO | ID: biblio-1532258

ABSTRACT

A escassez de dados científicos que validem os benefícios da diatomita para as propriedades físicas da resina composta Zirconfill® torna imperioso a realização de novos estudos, principalmente no tocante a utilização dessa resina contendo diatomita em restaurações semidiretas. Objetivo: Avaliar in vitro a polimerização e resistência de união entre uma resina composta contendo diatomita e de uma resina composta bulk-fill após 24 horas e após 06 meses de envelhecimento em água. Materiais e métodos: Foram utilizados 28 incisivos bovinos para produzir cavidades dentinárias cônicas (4,8 mm de diâmetro maior x 2,8 mm de diâmetro menor x 4 mm de espessura) e fator C de magnitude 3,1. Esses preparos cavitários (n=28) foram restaurados com as resinas compostas Filtek™ One Bulk-fill (BF) (3M ESPE) ou Zirconfill ® (ZF) (BM4), através da técnica semidireta, utilizando o sistema adesivo Single Bond Universal (3M ESPE) e o cimento resino dual Relyx™ Ultimate (3M ESPE). A análise da polimerização foi realizada através da razão base/topo (B/T) de dureza Vickers. E a resistência de união RU foi realizada através do teste de extrusão push-out em máquina de ensaio universal. As amostras foram armazenadas em água destilada a 37 ºC por 24 horas ou 06 meses, mas apenas a RU avaliou as amostras após 06 meses de envelhecimento. Os dados da B/T e da RU foram submetidos à análise de variância (ANOVA) a um e a dois critérios, respectivamente, com pós-teste de Tukey (p <0.05). Resultados: Não houve diferença estatisticamente significativa entre as resinas compostas na B/T. Para a RU, a resina composta ZF mostrou valores maiores do que a resina BF em ambos os tempos avaliados. Não houve diferença estatisticamente significativa de nenhuma resina na avaliação ao longo do tempo. Conclusão: A resina composta contendo diatomita mostrou-se promissora quando utilizada em restaurações semidiretas, visto que obteve resultados similar e até superior a resina composta bulk-fill (AU).


The scarcity of data validating scientific diatomite benefits for physical properties of Zirconfill® resin composite makes essential to develop new studies, especially regarding the use of this resin composite containing diatomite in semi-direct restorations. Aim: To evaluate in vitro the cure and bond strength between a resin composite containing diatomite and a bulk-fill resin composite after 24 hours and after 06 months of water storage. Materials and methods: Twenty-eight bovine incisors (n=28) were used to produce conical dentinal cavities (4,8 mm of larger diameter x 2,8 mm of smaller diameter x 4 mm of thickness) and C-factor of magnitude 3.1. These cavities were restored with Filtek™ One Bulk-Fill (BF) (3M ESPE) or Zirconfill® (ZF) (BM4) resin composites, through the semi-direct technique, using Scotchbond™ Universal (3M ESPE) adhesive system and Relyx™ Ultimate (3M ESPE) dual resin cement. The cure analysis was performed through bottom-to-top (B/T) ratio of vickers hardness, while bond strength (RU) was performed through the push-out test in a universal testing machine. The specimens were stored in distilled water at 37 ºC for 24 hours or 06 months, but only RU analyzed the specimens after 06 months aging. B/T and RU data were, respectively, submitted to one-way and two-way analysis of variance (ANOVA) with Tukey's post-test (p <0.05). Results: There was no statistically significant difference between the composite resins in B/T. For RU, the ZF composite resin showed higher values than the BF resin at both evaluated times. However, there was no statistically significant difference in resin composites over time. Conclusion: The resin composite containing diatomite showed promise when used in semi-direct restorations since it obtained similar or even superior results to bulk-fill resin composite (AU).


Subject(s)
Animals , Zirconium , Polymerization , Diatomaceous Earth , Time Factors , In Vitro Techniques/methods , Analysis of Variance , Dental Restoration, Permanent , Hardness Tests
11.
Acta odontol. latinoam ; 35(1): 10-15, Apr. 2022. graf
Article in English | LILACS-Express | LILACS | ID: biblio-1383419

ABSTRACT

ABSTRACT The aim of this study was to determine Vickers microhardness (HV) in bulk fill resins at different depths. Test specimens were prepared with different bulk fill resins: Filtek Bulk-Fill (3M ESPE) [FBF], Surefill SDR flow (Dentsply) [SDR], Fill-UP (COLTENE) [FU] and Surefill (Dentsply) [SF]. Semi-cylindrical test specimens were prepared in a mold 6 mm in diameter and 4 mm thick (n=5). A 1000 mW/cm2 light curing unit was applied (Coltolux LED - Coltene) for 20 seconds. HV was determined with three indentations (Vickers Future Tech FM300, 300 g, 8 s) at four depths: 1, 2, 3 and 4 mm from the top surface to the interior. Data were recorded immediately (t0) and 24 hours later (t24). Results were analyzed with two-way ANOVA (p<0.05), and multiple comparisons were performed using Tukey's test. Mean and SD of HV at t0 for each mm were: [FBF] t0: 49.23(4.65) / 48.32(3.36) / 44.38(2.06) / 40.59(2.58); [FBF] t24: 61.37(3.47) / 62.63(3.03) / 57.27(5.22) / 56.37(5.88); [SDR] t0: 27.81(3.13) / 28.07(2.4) / 27.24(2.94) / 25.71(3.0); [SDR] t24: 35.11(2.16) / 35.17(1.96) / 35.53(1.81) / 33.18(2.08); [FU] t0: 41.43(1.41) / 39.87(0.88) / 38.11(1.81) / 39.09(1.92); [FU] t24: 49.27(1.54) / 48.77(1.77) / 48.65(1.88) / 46.76(4.93); [SF] t0: 71.35(7.09) / 67.39(9.76) / 68.95(6.21) / 64.1(8.35); [SF] t24: 76.06(6.61) / 75.31(9.37) / 75.2(11.57) / 69.81(12.14). ANOVA showed significant effect of material, depth and recording time (p<0.05), and Tukey's test showed that recording sites (depths) differed significantly, giving four homogeneous groups. Under the conditions of this study, it can be concluded that microhardness of bulk-fill resins can be affected by depth and post-curing time.


RESUMEN El objetivo del presente estudio fue determinar la microdureza Vickers (HV) en resinas bulk-fill a diferentes profundidades. Se confeccionaron probetas semicilíndricas de 6 mm de diámetro y 4 mm de profundidad con diferentes composites de aplicación en bloque (Bulk-fill): Filtek Bulk-Fill (3M ESPE) [FBF], Surefill SDR flow (Dentsply) [SDR], Fill-UP (COLTENE) [FU] y Surefill (Dentsply) [SF]. Se polimerizaron con Coltolux LED (Coltene) con 1000 mW/cm2 durante 20s. La HV se determinó realizando 3 indentaciones con 300 g durante 8 s a 1,2 3 y 4 mm desde la superficie de la probeta hacia el interior inmediatamente después de curada y a las 24 h. Se utilizó un microdurómetro Vickers Future Tech FM300. Los resultados se analizaron estadísticamente mediante ANOVA de dos vías y Prueba de Tukey. La media y DS de HV fueron: [FBF] t0: 49,23(4,65) / 48,32(3,36) / 44,38(2,06) / 40,59(2,58); [FBF] t24: 61,37(3,47) / 62,63(3,03) / 57,27(5,22) / 56,37(5,88); [SDR] t0: 27,81(3,13) / 28,07(2,4) / 27,24(2,94) / 25,71(3,0); [SDR] t24: 35,11(2,16) / 35,17(1,96) / 35,53(1,81) / 33,18(2,08); [FU] t0: 41,43(1,41) / 39,87(0,88) / 38,11(1,81) / 39,09(1,92); [FU] t24: 49,27(1,54) / 48,77(1,77) / 48,65(1,88) / 46,76(4,93); [SF] t0: 71,35(7,09) / 67,39(9,76) / 68,95(6,21) / 64,1(8,35); [SF] t24: 76,06(6,61) / 75,31(9,37) / 75,2(11,57) / 69,81(12,14). La evaluación con análisis de varianza mostró el efecto significativo de las variables material, profundidad y momento del registro (p<0,05) y la prueba de Tukey mostró que los sitios de registro (profundidad) fueron estadísticamente significativos, dando cuatro grupos homogéneos. Bajo las condiciones de este estudio podemos concluir que la microdureza de las resinas de inserción en bloque se ve afectada por el nivel de profundidad y el tiempo pos curado.

12.
Rev. estomatol. Hered ; 32(1): 30-35, ene.-mar 2022. tab
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1389059

ABSTRACT

RESUMEN Antecedentes: Las resinas compuestas tipo Bulk-Fill (BF) son usadas en piezas posteriores con preparaciones extensas y profundas. Uno de sus beneficios más resaltantes es que, puede ser utilizada en incrementos de 4 a 5 mm, disminuyendo el tiempo de trabajo clínico. Sin embargo, en dientes con tratamientos de conductos estas preparaciones podrían tener mayor profundidad. Objetivos: Determinar el tiempo de fotoactivación necesario para polimerizar una resina Bulk-Fill ubicada en zonas profundas. Material y Métodos: En el presente estudio experimental in vitro, se confeccionaron especímenes de resina compuesta Filtek One Bulk Fill (3M ESPE, St. Paul, EE.UU.) de 5x5x5 mm color A2 fotoactivado a una distancia/tiempo de 0 mm/10 s, 0 mm/20 s, 3 mm/10 s, 3 mm/20 s, 3 mm/30 s y 3 mm/40 s (n=5). La microdureza superficial se registró en la superficie y en la base de cada espécimen. Resultados: El mayor valor de microdureza se registró en el grupo BF 0 mm/20 s y BF 3 mm/40 s (p<0,05), seguido por los grupos BF 3 mm/20 s y BF 3 mm/30 s (p>0,05). Los menores valores de microdureza se encontraron en los grupos BF 0 mm/10 s y BF 3 mm/10 s. Conclusión : Se requiere de 40 s de fotoactivación para polimerizar una resina Bulk-Fill ubicada en zonas profundas, cuando la lámpara está a una distancia de 3 mm de la superficie de la resina.


ABSTRACT Background: Bulk-fill composite resins (BF) are used in posterior restorations with extensive and deep preparations. One of the most outstanding benefits is that it can be used in increments of 4 to 5 mm, reducing clinical working time. However, in teeth with root canal treatment, these preparations could be deeper. Objectives: To determine the photoactivation time necessary to polymerize a Bulk-Fill resin located in deep areas. Material and Methods: In the present experimental in vitro study, specimens of Filtek One Bulk Fill composite resin (3M ESPE, St. Paul, USA) of 5x5x5 mm color A2 photoactivated at a distance/time of 0 mm/10 s, 0 mm/20 s, 3 mm/10 s, 3 mm/20 s, 3 mm/30 s and 3 mm/40 s (n=5) were fabricated. Surface microhardness was recorded on the surface and at the base of each specimen. Results: The highest microhardness value was recorded in group BF 0 mm/20 s and BF 3 mm/40 s (p<0.05), followed by groups BF 3 mm/20 s and BF 3 mm/30 s (p>0.05). The lowest microhardness values were found in the BF 0 mm/10 s and BF 3 mm/10 s groups. Conclusion: It takes 40 s of photoactivation to polymerize a Bulk-Fill resin located in deep areas, when the lamp is 3 mm away from the resin surface.

13.
Rev. odontol. UNESP (Online) ; 51: e20220043, 2022. tab
Article in Portuguese | LILACS, BBO | ID: biblio-1424239

ABSTRACT

Introdução: a inovação dos métodos de fotopolimerização foi proposta na tentativa de diminuir o estresse de contração de polimerização das resinas compostas e proporcionar maior conforto ao paciente, reduzindo o tempo de atendimento odontológico. Objetivo: avaliar a microdureza de duas resinas compostas nanoparticuladas submetidas a diferentes técnicas de polimerização. Material e método: quarenta espécimes foram divididos em quatro grupos (n=10) da seguinte forma: Filtek Z350 XT® + técnica imediata (GI); Filtek One Bulkfill® + técnica imediata (GII); Filtek Z350 XT® + técnica de pulso tardio (GIII); Filtek One Bulkfill® + técnica de pulso tardio (GIV). Após o armazenamento em água destilada à temperatura ambiente, os corpos de prova foram direcionados para a medição de microdureza. Utilizou-se teste T para comparação de técnicas e teste Two-Way ANOVA para calcular os efeitos das resinas compostas, técnicas de polimerização e interações referentes à variável dependente (p ≤0,05). Resultado: a resina Filtek Z350 XT® apresentou maior dureza na técnica imediata (GI - 312,45 ± 64,37) e pulso tardio (GIII - 244,50 ± 75,63) comparado à resina Filtek One Bulkfill®, em ambas as técnicas. Observaram-se maiores valores de dureza referentes à técnica imediata, com diferença estatística significativa em relação à resina testada (p = 0,04 - Filtek Z350 XT®; p = 0,03 - Filtek One Bulkfill®). Ambos os fatores isolados (resina e técnicas) apresentaram efeito nos valores de microdureza (p = 0,02 e p < 0,01, respectivamente). Conclusão: a técnica convencional demonstrou atingir maiores valores de dureza quando comparada à técnica de polimerização alternativa.


Introduction: the innovation of photopolymerization methods was proposed in an attempt to reduce the polymerization shrinkage stress of composite resins and also provide more comfort to patient reducing the chair time. The aim of this in vitro study was to assess the microhardness of two nanofilled composite resins subject to different curing techniques. Objective: assess the microhardness of two nanofilled composite resins subject to different curing techniques. Material and method: forty specimens were divided into four groups (N=10) as follows: Filtek Z350 XT® + immediate technique (GI); Filtek One Bulkfill® + immediate technique (GII); Filtek Z350 XT® + delayed pulse technique (GIII); Filtek One Bulkfill® + delayed pulse technique (GIV). After storage in distilled water at room temperature the specimens were assessed for microhardness measurement. T-test was used for comparison of techniques and two-way ANOVA used to calculate the effects of composite resins, curing techniques and their interactions on dependent variable (p set at 0.05). Result: Filtek Z350 XT® resin presented greater hardness on immediate technique (GI - 312,45 ± 64.37) and delayed pulse (GIII - 244,50 ± 75.63) compared to Filtek One Bulkfill® under both techniques. Overall, it was observed greater hardness values under immediate technique with a significant statistical difference apart of tested resin (p = 0.04 - Filtek Z350 XT®; p = 0.03 - Filtek One Bulkfill®). Both isolated factors (resin and techniques) presented effect on microhardness values (p = 0.02 and p < 0.01, respectively). Conclusion: the conventional technique demonstrated to reach higher hardness values when compared to the alternative polymerization technique


Subject(s)
In Vitro Techniques , Analysis of Variance , Composite Resins , Light-Curing of Dental Adhesives , Hardness Tests
14.
Braz. dent. sci ; 25(4): 1-9, 2022. tab, ilus
Article in English | LILACS, BBO | ID: biblio-1410481

ABSTRACT

Objective: The aim was to evaluate the influence of fluoride-releasing restorative materials in enamel and dentin microhardness. Material and Methods: 40 blocks (5x5x3 mm) from cervical third of human molars received a cavity preparation between the enamel and dentin, and the restorations were subjected to in vitro caries model. Specimens were randomly restored with (n=10): conventional glass ionomer cement (Ketac Cem, 3M ESPE); polyacid-modified composite resin (Ionoseal, VOCO); resin-modified glass ionomer cement (Ionofast, Biodinâmica); or microhybrid composite resin (Filtek Z250, 3M ESPE). The specimens were sectioned longitudinally and enamel and dentin Knoop microhardness were determined at different distances from the restorative material (100, 200 and 300 µm) and depth of surface (20, 40 and 60 µm). The data were submitted to three-way repeated measures ANOVA and Tukey ́s test ( α =0.05). Results: For enamel, the double interactions between material x distance and material x depth were statistically significant. In all depths and distances, the highest values of enamel microhardness were observed for Ketac Cem. In dentin, the materials differed statistically from each other, and Ionoseal obtained higher microhardness values than those found in Ionofast. Conclusion: Conventional glass ionomer cement is more effective in preventing enamel demineralization around restoration followed by the polyacid-modified composite resin. In dentin, the polyacid-modified composite resin obtained better performance than resin-modified glass ionomer cement. (AU)


Objetivo: O objetivo foi avaliar a influência de materiais restauradores liberadores de flúor na microdureza do esmalte e da dentina. Material e Métodos: 40 blocos (5x5x3 mm) do terço cervical de molares humanos receberam preparo cavitário entre esmalte e dentina, e após a restauração foram submetidas a um modelo in vitro de cárie. As amostras foram restauradas aleatoriamente com (n=10): cimento de ionômero de vidro convencional (Ketac Cem, 3M ESPE); resina composta modificada por poliácidos (Ionoseal, VOCO); cimento de ionômero de vidro modificado por resina (Ionofast, Biodinâmica); ou resina composta microhíbrida (Filtek Z250, 3M ESPE). As amostras foram seccionadas longitudinalmente e a microdureza Knoop de esmalte e dentina foi determinada em diferentes distâncias do material restaurador (100, 200 e 300 µm) e profundidade de superfície (20, 40 e 60 µm). Os dados foram submetidos à ANOVA para medidas repetidas de três fatores e teste de Tukey (α =0,05). Resultados: Para o esmalte, as duplas interações entre material x distância e material x profundidade foram estatisticamente significativas. Em todas as profundidades e distâncias, os maiores valores de microdureza do esmalte foram observados para o Ketac Cem. Na dentina, Ionoseal obteve valores de microdureza superiores aos encontrados no Ionofast. Conclusão:O cimento de ionômero de vidro convencional é mais eficaz na prevenção da desmineralização do esmalte ao redor da restauração, seguido pela resina composta modificada por poliácidos. Na dentina, a resina composta modificada por poliácidos obteve melhor desempenho que o cimento de ionômero de vidro modificado por resina. (AU)


Subject(s)
Composite Resins , Compomers , Dental Caries , Glass Ionomer Cements , Hardness Tests
15.
Braz. dent. sci ; 25(2): 1-8, 2022. tab
Article in English | LILACS, BBO | ID: biblio-1367395

ABSTRACT

Objective: This study evaluated the influence of calcium lactate and sodium fluoride mouthwashes on enamel microhardness and dentin permeability during in-office bleaching. Material and Methods: For the microhardness evaluation, enamel blocks were randomly submitted to different treatments associated with in-office bleaching agent using 40% hydrogen peroxide (Opalescence Boost PF 40%/ Ultradent; 3 sessions x 40-minute each) (n = 10): 1) Control: application of bleaching agent; 2) Calcium lactate: 1-minute immersion before bleaching treatment; 3) Sodium fluoride: immersion for 1 minute before bleaching treatment; 4) Calcium lactate + sodium fluoride: 1 minute immersion in calcium lactate solution, followed by 1 minute immersion in sodium fluoride before bleaching treatment. Dentin discs received the same treatment protocols (n = 10) to evaluate permeability. Knoop microhardness and dentin permeability assessments were performed twice (at baseline and 48 hours after the end of bleaching treatment). Results: The generalized linear model considering the design of repeated measures over time showed that there was no significant difference between treatments (p = 0.9577) and between assessments (p = 0.3267) regarding Knoop microhardness. Kruskal Wallis and Dunn tests showed that calcium lactate immersion before bleaching treatment provided higher dentin permeability than other groups (p = 0.0009). Conclusion: The use of sodium fluoride solution and calcium lactate in association with in-office bleaching treatment did not influence the microhardness of tooth enamel, although calcium lactate may increase dentin permeability. (AU)


Objetivo: Este estudo avaliou a influência dos enxaguatórios bucais com lactato de cálcio e fluoreto de sódio na microdureza do esmalte e na permeabilidade da dentina durante o clareamento em consultório. Material e Métodos: Para avaliação da microdureza, blocos de esmalte foram submetidos aleatoriamente a diferentes tratamentos associados a agente clareador em consultório com peróxido de hidrogênio 40% (Opalescence Boost PF 40% / Ultradent; 3 sessões x 40 minutos cada) (n = 10): 1) Controle: aplicação de agente clareador; 2) Lactato de cálcio: imersão de 1 minuto antes do tratamento clareador; 3) Fluoreto de sódio: imersão por 1 minuto antes do tratamento clareador; 4) Lactato de cálcio + fluoreto de sódio: 1 minuto de imersão em solução de lactato de cálcio, seguido de 1 minuto de imersão em fluoreto de sódio antes do tratamento clareador. Os discos de dentina receberam os mesmos protocolos de tratamento (n = 10) para avaliar a permeabilidade. As avaliações da microdureza Knoop e da permeabilidade dentinária foram realizadas duas vezes (no início do estudo e 48 horas após o término do tratamento clareador). Resultados: O modelo linear generalizado considerando o delineamento de medidas repetidas ao longo do tempo mostrou que não houve diferença significativa entre os tratamentos (p = 0,9577) e entre as avaliações (p = 0,3267) em relação à microdureza Knoop. Os testes de Kruskal Wallis e Dunn mostraram que a imersão de lactato de cálcio antes do tratamento clareador proporcionou maior permeabilidade dentinária do que os outros grupos (p = 0,0009). Conclusão: O uso de fluoreto de sódio e lactato de cálcio associado ao clareamento em consultório não influenciou a microdureza do esmalte dentário, embora o lactato de cálcio possa aumentar a permeabilidade dentinária (AU)


Subject(s)
Sodium Fluoride , Tooth Bleaching , Calcarea Lactica , Dentin , Hardness Tests
16.
Odovtos (En línea) ; 23(3)dic. 2021.
Article in English | LILACS, SaludCR | ID: biblio-1386559

ABSTRACT

ABSTRACT: There is insufficient information about the chairside polishing methods of polyether ether ketone material. Therefore, it is aimed in this study to investigate the effects of different polishing processes on polyether ether ketone surface roughness and hardness. A total of 66 disc-shaped specimens made of polyether ether ketone were used in this study. The specimens were polished conventionally and randomly divided into three groups (n=22). One group was designated as the control group, and no further treatment was applied. In the other two groups, the specimens' surfaces were abraded with diamond burs and polished using two different polishing kits. Their surface roughness and Vickers hardness were measured, and environmental scanning electron microscopy and atomic force microscopy examinations were performed. The data were statistically analysed using analysis of variance and Tukey's honest significant difference test (α=0.05). There were no statistically significant differences between the control and polishing kit groups in terms of either surface roughness or Vickers hardness (p>0.05). The polishing kits can be used reliably and effectively for polishing polyether ether ketone materials.


RESUMEN: No existe información suficiente sobre los métodos de pulido del material poliéter éter cetona. Por tanto, este estudio tiene como objetivo evaluar el efecto de diferentes procedimientos de pulido sobre la rugosidad y dureza de superficie de un material a base de poliéter éter acetona. Un total de 66 muestras en forma de disco fueron realizadas. Los especímenes fueron divididos en tres grupos (n=22). Un grupo fue designado como grupo de control, siendo que no se aplicó ningún tratamiento. En los otros dos grupos, las superficies de las muestras se lijaron con fresas de diamante y se pulieron con dos kits de pulido diferentes. Se investigó la rugosidad de superficie y la dureza Vickers en los diferentes grupos. También fueron evaluadas muestras representativas en microscopía electrónica de barrido y microscopía de fuerza atómica. Los datos se analizaron estadísticamente mediante el análisis de varianza (ANOVA) y el método de Tukey (α=0.05). No hubo diferencias estadísticamente significativas entre los grupos en términos de rugosidad de superficie o Dureza Vickers (p>0,05). Los kits de pulido se pueden utilizar de forma eficaz para el pulido de materiales a base de poliéter éter acetona.


Subject(s)
Polyethylenes , Dental Polishing , Dentifrices/analysis
17.
J. health sci. (Londrina) ; 23(3): 234-237, 20210920.
Article in English | LILACS-Express | LILACS | ID: biblio-1292813

ABSTRACT

Bulk Fill resins are a class of resin composites widely used today and have low polymerization shrinkage. However, these materials need an appropriate light curing technique to have good physical and mechanical properties. The objective of this study was to evaluate the surface microhardness of Bulk Fill resins after their light-curing with two types of high- power light curing devices, using three techniques. 30 specimens were made with a nanoparticulate composite resin Opus Bulk Fill (FGM) and were divided into three groups according to the device and intensity of light curing: Group 1 - light curing with the Emitter B device (Schuster); Group 2 - light curing with the Valo device (Ultradent) at Standard power; and Group 3 - light curing with the Valo device at high power. Higher values of top surface microhardness were observed in Group 3 (microhardness = 53.6 µm), followed by Group 2 (microhardness = 52.1 µm) and Group 1 (microhardness = 33.1 µm), with p values <0.05. Therefore, the Valo light curing unit, in the two powers used, provided greater surface microhardness for the studied specimens. (AU)


Resinas Bulk Fill são uma classe de compósitos resinosos bastante utilizados atualmente e apresentam baixa contração de polimerização. Entretanto, esses materiais necessitam de uma adequada técnica de fotopolimerização para que apresentem boas propriedades físicas e mecânicas. O objetivo deste estudo foi avaliar a microdureza superficial de resinas Bulk Fill fotopolimerizadas com dois tipos de aparelhos fotopolimerizadores de alta potência, em três técnicas de utilização. Foram confeccionados 30 corpos de prova com uma resina composta nanoparticulada Opus Bulk Fill (FGM) e divididos em três grupos de acordo com o aparelho e intensidade de fotopolimerização: Grupo 1 ­ fotopolimerização com o aparelho Emitter B. (Schuster), Grupo 2 ­ fotopolimerização com o aparelho Valo (Ultradent) na potência Standard, Grupo 3 ­ fotopolimerização com o aparelho Valo em alta potência, posteriormente foi realizado o teste de microdureza de Vickers na região superficial de topo dos corpos de prova. Observou-se maiores valores de microdureza superficial de topo no Grupo 3 (microdureza= 53,6 µm), seguido pelo Grupo 2 (microdureza= 52,1 µm) e Grupo 1 (microdureza= 33,1 µm), com valores de p<0,05. Assim sendo, o aparelho fotopolimerizador Valo, nas duas potências utilizadas, forneceu maior microdureza superficial para os corpos de prova estudados. (AU)

18.
RFO UPF ; 26(2): 299-312, 20210808. tab
Article in Portuguese | LILACS, BBO | ID: biblio-1452536

ABSTRACT

Objetivo: Várias fontes de luz têm sido utilizadas desde que os materiais fotoativados foram introduzidos na odontologia. Diodos emissores de luz (LEDs) se popularizaram como a principal opção para a polimerização dos materiais restauradores. O objetivo nessa revisão da literatura foi avaliar a influência das fontes de luz emitidas por diodo (LEDs) de segunda e terceira geração sobre a dureza de compósitos restauradores. Revisão de literatura: Nas bases de dados PubMed e Google Scholar foram pré-selecionados 239 artigos na língua inglesa entre os anos de 2010 e 2020, utilizando os termos: lightcuring, LED light sources, and dental LEDs. Dos 239 artigos inicialmente selecionados, 37 artigos foram avaliados devido aos critérios de inclusão/exclusão no estudo. Considerações finais: Vários estudos apontaram diferenças importantes na dureza dos compósitos restauradores testados, tanto na superfície de topo quanto na base. No entanto, essas diferenças estavam mais associadas a características como: estado de conservação do LED, irradiância, tempo de ativação, espectro de emissão dos aparelhos e sua compatibilidade ao fotoiniciador presente no compósito. Assim, podemos considerar que o monitoramento das condições do aparelho, e a escolha correta da fonte de luz de acordo com o compósito a ser utilizado são essenciais para maximizar a dureza dos compósitos restauradores, pois embora os aparelhos de terceira geração sejam preferencialmente indicados para compósitos com fotoiniciadores alternativos, os aparelhos que emitem luz azul apresentam vantagens quando o compósito é ativado apenas pela Canforoquinona.(AU)


Objective: Several light sources have been used since the light-curing materials were introduced in dentistry. Light-emitting diodes (LEDs) have become popular as the main option for the polymerization of restorative materials. This literature review aimed to evaluate the influence of second and third generation Light-emitting Diode (LEDs) sources on the hardness of restorative composites. Literature Review: In the PubMed and Google Scholar databases, 239 scientific papers in English were pre-selected between 2010 and 2020 using light-curing, LED light sources, and dental LEDs. After reading, 37 articles were selected to compose the review. Several studies have pointed out significant differences in the hardness of the tested restorative composites, both on the top and base surfaces. However, these differences were more associated with characteristics such as: LED conservation conditions, irradiance, curing time, the emission spectrum of the devices and their compatibility with the photoinitiator used in the composite. Final Considerations: Thus, it can be considered that monitoring the condition of the device and the correct choice of light sources according to the composite to be used is essential to maximize the hardness of the restorative composites, because although third-generation devices are preferably indicated for composites with alternative photoinitiators, devices that emit blue light have advantages when the composite is activated only by Camphorquinone.(AU)


Subject(s)
Humans , Composite Resins/chemistry , Curing Lights, Dental , Hardness , Dental Materials/chemistry , Light-Curing of Dental Adhesives/methods , Polymerization
19.
Odovtos (En línea) ; 23(2)ago. 2021.
Article in English | LILACS, SaludCR | ID: biblio-1386539

ABSTRACT

ABSTRACT: The purpose of this study was to evaluate and compare the effect of carbonated beverage on the surface microhardness of two acrylic materials used to fabricate temporary restorations. The study was experimental in vitro. Forty blocks of acrylic resins used in provisional restorations were made, 20 from Alike® (GC AMERICA INC., Lot 1712161) and 20 from Acryptemp® (Zhermack S.P.A., Lot 302334). After that, the blocks were immersed in distilled water for 24 hours. After this time, the initial surface microhardness was measured. Then the 20 samples of the experimental group were immersed in a carbonated drink (coca cola - soda) for 12 minutes per day, for 5 days. Finally, the final surface microhardness was measured using the Vickers microdurometer. Measures of central tendency and dispersion were used, and the Student's t test and ANOVA were performed. A mean surface microhardness of 8.8 and 7.2HV was found for the PMMA resin group (Initial and final respectively), and 9.5 and 8HV for the bisacrylate group. Statistically significant differences were found when comparing the beginning and end of each group and when comparing the two materials. The acrylic resin of polymethylmethacrylate (Alike® GC AMERICA INC.) Presented higher surface microhardness compared to the bis acrylic resin (Acrytemp® Zhermack S.P.A), after being exposed to a carbonated drink.


RESUMEN: El propósito de este estudio fue evaluar y comparar el efecto de la bebida carbonatada en la microdureza superficial de dos materiales acrílicos utilizados para confeccionar restauraciones provisionales. El estudio fue experimental in vitro. Se confeccionaron 40 bloques de resinas acrílicas utilizadas en provisorios, 20 de Alike® (GC AMERICA INC., Lote 1712161) y 20 de Acryptemp® (Zhermack S.P.A., Lote 302334). Posterior a ello, se sumergió los bloques en agua destilada por 24 horas. Pasado este tiempo se procedió a medir la microdureza superficial inicial. Luego las 20 muestras del grupo experimental se sumergieron en una bebida carbonatada (coca cola-gaseosa) durante 12 minutos por día, durante 5 días. Por último se midió la microdureza superficial final mediante el microdurómetro de Vickers. Se utilizaron medidas de tendencia central, dispersión y se realizaron la prueba t de Student y ANOVA. Se encontró una microdureza superficial media de 8,8 y 7,2HV para el grupo de resina PMMA (Inicial y final respectivamente), y 9,5 y 8HV para el grupo de bisacrilato. Se halló diferencias estadísticamente significativas al comparar el inicio y final de cada grupo y al comparar los dos materiales. La resina acrílica de polimetilmetacrilato (Alike® GC AMERICA INC.) presentó mayor microdureza superficial en comparación con la resina bis acrílica (Acrytemp® Zhermack S.P.A), después de ser expuestas a una bebida carbonatada.


Subject(s)
Acrylic Resins/analysis , Carbonated Beverages/adverse effects , Peru , Hardness
20.
Dent. press endod ; 11(2): 18-24, maio-ago.2021. Tab, Ilus
Article in English | LILACS | ID: biblio-1359533

ABSTRACT

Objetivo: Avaliar a microdureza do tecido dentinário bovino após a exposição a soluções irrigantes em Endodontia. Métodos: Amostras de dentina bovina foram divididas aleatoriamente em seis grupos (n=10) e submetidas aos seguintes tratamentos: soro (60 min); NaOCl a 2,5% (hipoclorito de sódio) (60 min); CHX gel a 2% (clorexidina) (60 min); EDTA a 17% (ácido etilenodiaminotetracético) (1 min); NaOCl a 2,5% + EDTA a 17% (60 + 1 min) e CHX gel a 2% + EDTA a 17% (60 + 1 min). A microdureza Knoop foi utilizada para as medidas. Os dados foram avaliados pelo teste ANOVA, seguido pelo método de Duncan, com nível de significância de 5%. Resultados: A solução de NaOCl a 2,5%, seguida ou não de EDTA a 17%, reduziu significativamente a microdureza dentinária (p<0,05). A exposição à clorexidina gel a 2%, seguida ou não de EDTA a 17%, não resultou em alterações na microdureza dentinária (p>0,05). Conclusão: NaOCl a 2,5% reduziu significativamente a microdureza da dentina bovina após 60 minutos de exposição (AU).


Objective: Evaluate the microhardness of bovine den- tin tissue after exposure to endodontic irrigating solu- tions. Methods: Bovine dentin samples were randomly divided into 6 groups (n = 10) and submitted to the following treatments: saline (60 min); 2.5% NaOCl (sodium hypochlorite) (60 min); 2% gel CHX (chlorhexidine) (60 min); 17% EDTA (Ethylenediamine tetraacetic acid) (1 min); 2.5% NaOCl + 17% EDTA (60 + 1 min) and 2% gel CHX + 17% EDTA (60 + 1 min). Knoop microhardness was used for the measurements. Data were evaluated by ANOVA test followed by Duncans Method at 5% signifi- cance level. Results: The 2.5% NaOCl solution, followed or not by 17% EDTA, significative reduced the dentin microhardness (p <0.05). Exposures to 2% gel chlorexidine, followed or not by 17% EDTA, did not result in alterations at dentin tissue microhardness (p>0.05). Conclusion: 2.5% NaOCl significatively reduces the microhardness of bovine dentin after 60 minutes of exposure (AU).


Subject(s)
Animals , Root Canal Irrigants , Sodium Hypochlorite , Chlorhexidine , Dentin , Hardness
SELECTION OF CITATIONS
SEARCH DETAIL